Install any skill in seconds. Free to start, no credit card required.
Get Started Free →cyberstrikeus/T0827_loss-of-control
Adversaries may seek to achieve a sustained loss of control or a runaway condition in which operators cannot issue any commands even if the malicious interference has subsided.
Passed 21 of 23 test cases with the skill, and 13 of 23 without it.
and 14 more in the full report
8 fixed13 passed either way2 still failing0 broke
Tokens, turns and time describe resource use, not a dollar price.
One of 8 test cases the skill fixed. Same model, same prompt, with and without the skill.
During an ICS security gap analysis for complete loss of operator control, how many distinct MITRE ATT&CK mitigations must be evaluated for presence or misconfiguration?
| Checked | Without skill | With skill |
|---|---|---|
| States that 3 mitigations are evaluated for this technique. | Missed | Passed |
| Includes mitigation M0953 Data Backup. | Missed | Passed |
| Includes mitigation M0811 Redundancy of Service. | Missed | Passed |
| Includes mitigation M0810 Out-of-Band Communications Channel. | Missed | Passed |
The instructions your model reads when the skill loads.
Adversaries may seek to achieve a sustained loss of control or a runaway condition in which operators cannot issue any commands even if the malicious interference has subsided.
The German Federal Office for Information Security (BSI) reported a targeted attack on a steel mill in its 2014 IT Security Report. These targeted attacks affected industrial operations and resulted in breakdowns of control system components and even entire installations. As a result of these breakdowns, massive impact resulted in damage and unsafe conditions from the uncontrolled shutdown of a blast furnace.
Platforms: ICS
Determine if the target ICS/SCADA environment is susceptible to Loss of Control by examining operational technology systems and network architecture.
Review whether mitigations for T0827 are in place. If defenses are absent or misconfigured, this technique may be exploitable in the ICS environment.
Take and store data backups from end user systems and critical servers. Ensure backup and storage systems are hardened and kept separate from the corporate network to prevent compromise. Maintain and exercise incident response plans , including the management of gold-copy back-up images and configurations for key systems to enable quick recovery and response from adversarial activities that impact control, view, or availability.
Hot-standbys in diverse locations can ensure continued operations if the primarily system are compromised or unavailable. At the network layer, protocols such as the Parallel Redundancy Protocol can be used to simultaneously use redundant and diverse communication over a local network.
test cases passed, vs 13 / 23 without
Published skills whose descriptions closely match this one, with their headline benchmark lift.
More skills from the same source and nearby in the registry, with their headline benchmark lift.