Install any skill in seconds. Free to start, no credit card required.
Get Started Free →Lab automation platform for Flex/OT-2 robots. Write Protocol API v2 protocols, liquid handling, hardware modules (heater-shaker, thermocycler), labware management, for automated pipetting workflows.
.claude/skills/opentrons-integration/SKILL.md| Test case | Without → With | Effect | Δ tokens | Δ turns |
|---|---|---|---|---|
| case-05 | ✗→✓ | ▲ Improved | — | — |
| case-17 | ✗→✓ | ▲ Improved | — | — |
| case-09 | ✗→✓ | ▲ Improved | — | — |
| case-12 | ✗→✓ | ▲ Improved | — | — |
| case-04 | ✓→✓ | = Same ✓ | — | — |
Opentrons is a Python-based lab automation platform for Flex and OT-2 robots. Write Protocol API v2 protocols for liquid handling, control hardware modules (heater-shaker, thermocycler), manage labware, for automated pipetting workflows.
This skill should be used when:
Every Opentrons protocol follows a standard structure:
pythonfrom opentrons import protocol_api # Metadata metadata = { 'protocolName': 'My Protocol', 'author': 'Name <email@example.com>', 'description': 'Protocol description', 'apiLevel': '2.19' # Use latest available API version } # Requirements (optional) requirements = { 'robotType': 'Flex', # or 'OT-2' 'apiLevel': '2.19' } # Run function def run(protocol: protocol_api.ProtocolContext): # Protocol commands go here pass
Key elements:
protocol_api from opentronsmetadata dict with protocolName, author, description, apiLevelrequirements dict for robot type and API versionrun() function receiving ProtocolContext as parameterrun() functionLoading Instruments (Pipettes):
pythondef run(protocol: protocol_api.ProtocolContext): # Load pipette on specific mount left_pipette = protocol.load_instrument( 'p1000_single_flex', # Instrument name 'left', # Mount: 'left' or 'right' tip_racks=[tip_rack] # List of tip rack labware objects )
Common pipette names:
p50_single_flex, p1000_single_flex, p50_multi_flex, p1000_multi_flexp20_single_gen2, p300_single_gen2, p1000_single_gen2, p20_multi_gen2, p300_multi_gen2Loading Labware:
python# Load labware directly on deck plate = protocol.load_labware( 'corning_96_wellplate_360ul_flat', # Labware API name 'D1', # Deck slot (Flex: A1-D3, OT-2: 1-11) label='Sample Plate' # Optional display label ) # Load tip rack tip_rack = protocol.load_labware('opentrons_flex_96_tiprack_1000ul', 'C1') # Load labware on adapter adapter = protocol.load_adapter('opentrons_flex_96_tiprack_adapter', 'B1') tips = adapter.load_labware('opentrons_flex_96_tiprack_200ul')
Loading Modules:
python# Temperature module temp_module = protocol.load_module('temperature module gen2', 'D3') temp_plate = temp_module.load_labware('corning_96_wellplate_360ul_flat') # Magnetic module mag_module = protocol.load_module('magnetic module gen2', 'C2') mag_plate = mag_module.load_labware('nest_96_wellplate_100ul_pcr_full_skirt') # Heater-Shaker module hs_module = protocol.load_module('heaterShakerModuleV1', 'D1') hs_plate = hs_module.load_labware('corning_96_wellplate_360ul_flat') # Thermocycler module (takes up specific slots automatically) tc_module = protocol.load_module('thermocyclerModuleV2') tc_plate = tc_module.load_labware('nest_96_wellplate_100ul_pcr_full_skirt')
Basic Operations:
python# Pick up tip pipette.pick_up_tip() # Aspirate (draw liquid in) pipette.aspirate( volume=100, # Volume in µL location=source['A1'] # Well or location object ) # Dispense (expel liquid) pipette.dispense( volume=100, location=dest['B1'] ) # Drop tip pipette.drop_tip() # Return tip to rack pipette.return_tip()
Complex Operations:
python# Transfer (combines pick_up, aspirate, dispense, drop_tip) pipette.transfer( volume=100, source=source_plate['A1'], dest=dest_plate['B1'], new_tip='always' # 'always', 'once', or 'never' ) # Distribute (one source to multiple destinations) pipette.distribute( volume=50, source=reservoir['A1'], dest=[plate['A1'], plate['A2'], plate['A3']], new_tip='once' ) # Consolidate (multiple sources to one destination) pipette.consolidate( volume=50, source=[plate['A1'], plate['A2'], plate['A3']], dest=reservoir['A1'], new_tip='once' )
Advanced Techniques:
python# Mix (aspirate and dispense in same location) pipette.mix( repetitions=3, volume=50, location=plate['A1'] ) # Air gap (prevent dripping) pipette.aspirate(100, source['A1']) pipette.air_gap(20) # 20µL air gap pipette.dispense(120, dest['A1']) # Blow out (expel remaining liquid) pipette.blow_out(location=dest['A1'].top()) # Touch tip (remove droplets on tip exterior) pipette.touch_tip(location=plate['A1'])
Flow Rate Control:
python# Set flow rates (µL/s) pipette.flow_rate.aspirate = 150 pipette.flow_rate.dispense = 300 pipette.flow_rate.blow_out = 400
Well Access Methods:
python# By name well_a1 = plate['A1'] # By index first_well = plate.wells()[0] # All wells all_wells = plate.wells() # Returns list # By rows rows = plate.rows() # Returns list of lists row_a = plate.rows()[0] # All wells in row A # By columns columns = plate.columns() # Returns list of lists column_1 = plate.columns()[0] # All wells in column 1 # Wells by name (dictionary) wells_dict = plate.wells_by_name() # {'A1': Well, 'A2': Well, ...}
Location Methods:
python# Top of well (default: 1mm below top) pipette.aspirate(100, well.top()) pipette.aspirate(100, well.top(z=5)) # 5mm above top # Bottom of well (default: 1mm above bottom) pipette.aspirate(100, well.bottom()) pipette.aspirate(100, well.bottom(z=2)) # 2mm above bottom # Center of well pipette.aspirate(100, well.center())
Temperature Module:
python# Set temperature temp_module.set_temperature(celsius=4) # Wait for temperature temp_module.await_temperature(celsius=4) # Deactivate temp_module.deactivate() # Check status current_temp = temp_module.temperature # Current temperature target_temp = temp_module.target # Target temperature
Magnetic Module:
python# Engage (raise magnets) mag_module.engage(height_from_base=10) # mm from labware base # Disengage (lower magnets) mag_module.disengage() # Check status is_engaged = mag_module.status # 'engaged' or 'disengaged'
Heater-Shaker Module:
python# Set temperature hs_module.set_target_temperature(celsius=37) # Wait for temperature hs_module.wait_for_temperature() # Set shake speed hs_module.set_and_wait_for_shake_speed(rpm=500) # Close labware latch hs_module.close_labware_latch() # Open labware latch hs_module.open_labware_latch() # Deactivate heater hs_module.deactivate_heater() # Deactivate shaker hs_module.deactivate_shaker()
Thermocycler Module:
python# Open lid tc_module.open_lid() # Close lid tc_module.close_lid() # Set lid temperature tc_module.set_lid_temperature(celsius=105) # Set block temperature tc_module.set_block_temperature( temperature=95, hold_time_seconds=30, hold_time_minutes=0.5, block_max_volume=50 # µL per well ) # Execute profile (PCR cycling) profile = [ {'temperature': 95, 'hold_time_seconds': 30}, {'temperature': 57, 'hold_time_seconds': 30}, {'temperature': 72, 'hold_time_seconds': 60} ] tc_module.execute_profile( steps=profile, repetitions=30, block_max_volume=50 ) # Deactivate tc_module.deactivate_lid() tc_module.deactivate_block()
Absorbance Plate Reader:
python# Initialize and read result = plate_reader.read(wavelengths=[450, 650]) # Access readings absorbance_data = result # Dict with wavelength keys
Define Liquids:
python# Define liquid types water = protocol.define_liquid( name='Water', description='Ultrapure water', display_color='#0000FF' # Hex color code ) sample = protocol.define_liquid( name='Sample', description='Cell lysate sample', display_color='#FF0000' )
Load Liquids into Wells:
python# Load liquid into specific wells reservoir['A1'].load_liquid(liquid=water, volume=50000) # µL plate['A1'].load_liquid(liquid=sample, volume=100) # Mark wells as empty plate['B1'].load_empty()
Execution Control:
python# Pause protocol protocol.pause(msg='Replace tip box and resume') # Delay protocol.delay(seconds=60) protocol.delay(minutes=5) # Comment (appears in logs) protocol.comment('Starting serial dilution') # Home robot protocol.home()
Conditional Logic:
python# Check if simulating if protocol.is_simulating(): protocol.comment('Running in simulation mode') else: protocol.comment('Running on actual robot')
Rail Lights (Flex only):
python# Turn lights on protocol.set_rail_lights(on=True) # Turn lights off protocol.set_rail_lights(on=False)
When using multi-channel pipettes:
python# Load 8-channel pipette multi_pipette = protocol.load_instrument( 'p300_multi_gen2', 'left', tip_racks=[tips] ) # Access entire column with single well reference multi_pipette.transfer( volume=100, source=source_plate['A1'], # Accesses entire column 1 dest=dest_plate['A1'] # Dispenses to entire column 1 ) # Use rows() for row-wise operations for row in plate.rows(): multi_pipette.transfer(100, reservoir['A1'], row[0])
Serial Dilution:
pythondef run(protocol: protocol_api.ProtocolContext): # Load labware tips = protocol.load_labware('opentrons_flex_96_tiprack_200ul', 'D1') reservoir = protocol.load_labware('nest_12_reservoir_15ml', 'D2') plate = protocol.load_labware('corning_96_wellplate_360ul_flat', 'D3') # Load pipette p300 = protocol.load_instrument('p300_single_flex', 'left', tip_racks=[tips]) # Add diluent to all wells except first p300.transfer(100, reservoir['A1'], plate.rows()[0][1:]) # Serial dilution across row p300.transfer( 100, plate.rows()[0][:11], # Source: wells 0-10 plate.rows()[0][1:], # Dest: wells 1-11 mix_after=(3, 50), # Mix 3x with 50µL after dispense new_tip='always' )
Plate Replication:
pythondef run(protocol: protocol_api.ProtocolContext): # Load labware tips = protocol.load_labware('opentrons_flex_96_tiprack_1000ul', 'C1') source = protocol.load_labware('corning_96_wellplate_360ul_flat', 'D1') dest = protocol.load_labware('corning_96_wellplate_360ul_flat', 'D2') # Load pipette p1000 = protocol.load_instrument('p1000_single_flex', 'left', tip_racks=[tips]) # Transfer from all wells in source to dest p1000.transfer( 100, source.wells(), dest.wells(), new_tip='always' )
PCR Setup:
pythondef run(protocol: protocol_api.ProtocolContext): # Load thermocycler tc_mod = protocol.load_module('thermocyclerModuleV2') tc_plate = tc_mod.load_labware('nest_96_wellplate_100ul_pcr_full_skirt') # Load tips and reagents tips = protocol.load_labware('opentrons_flex_96_tiprack_200ul', 'C1') reagents = protocol.load_labware('opentrons_24_tuberack_nest_1.5ml_snapcap', 'D1') # Load pipette p300 = protocol.load_instrument('p300_single_flex', 'left', tip_racks=[tips]) # Open thermocycler lid tc_mod.open_lid() # Distribute master mix p300.distribute( 20, reagents['A1'], tc_plate.wells(), new_tip='once' ) # Add samples (example for first 8 wells) for i, well in enumerate(tc_plate.wells()[:8]): p300.transfer(5, reagents.wells()[i+1], well, new_tip='always') # Run PCR tc_mod.close_lid() tc_mod.set_lid_temperature(105) # PCR profile tc_mod.set_block_temperature(95, hold_time_seconds=180) profile = [ {'temperature': 95, 'hold_time_seconds': 15}, {'temperature': 60, 'hold_time_seconds': 30}, {'temperature': 72, 'hold_time_seconds': 30} ] tc_mod.execute_profile(steps=profile, repetitions=35, block_max_volume=25) tc_mod.set_block_temperature(72, hold_time_minutes=5) tc_mod.set_block_temperature(4) tc_mod.deactivate_lid() tc_mod.open_lid()
protocol.comment() for debugging and loggingnew_tip='once' when appropriate to save tipsCommon Issues:
For detailed API documentation, see references/api_reference.md in this skill directory.
For example protocol templates, see scripts/ directory.
| Case | Status | Duration (ms) | Turns | Tokens | Tool calls | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Without | With | Δ | Without | With | Δ | Without | With | Δ | Without | With | Δ | ||
case-18 | fail→fail | — | — | — | — | — | — | — | — | — | — | — | — |
case-21 | fail→fail | — | — | — | — | — | — | — | — | — | — | — | — |
case-13 | fail→fail | — | — | — | — | — | — | — | — | — | — | — | — |
case-05 | fail→pass | — | — | — | — | — | — | — | — | — | — | — | — |
case-17 | fail→pass | — | — | — | — | — | — | — | — | — | — | — | — |
case-09 | fail→pass | — | — | — | — | — | — | — | — | — | — | — | — |
case-03 | fail→fail | — | — | — | — | — | — | — | — | — | — | — | — |
case-15 | fail→fail | — | — | — | — | — | — | — | — | — | — | — | — |
case-08 | fail→fail | — | — | — | — | — | — | — | — | — | — | — | — |
case-16 | fail→fail | — | — | — | — | — | — | — | — | — | — | — | — |
case-04 | pass→pass | — | — | — | — | — | — | — | — | — | — | — | — |
case-14 | fail→fail | — | — | — | — | — | — | — | — | — | — | — | — |
case-19 | fail→fail | — | — | — | — | — | — | — | — | — | — | — | — |
case-02 | fail→fail | — | — | — | — | — | — | — | — | — | — | — | — |
case-01 | pass→pass | — | — | — | — | — | — | — | — | — | — | — | — |
case-11 | fail→fail | — | — | — | — | — | — | — | — | — | — | — | — |
case-10 | fail→fail | — | — | — | — | — | — | — | — | — | — | — | — |
case-12 | fail→pass | — | — | — | — | — | — | — | — | — | — | — | — |
case-20 | fail→fail | — | — | — | — | — | — | — | — | — | — | — | — |
case-22 | fail→fail | — | — | — | — | — | — | — | — | — | — | — | — |
case-07 | fail→fail | — | — | — | — | — | — | — | — | — | — | — | — |
case-06 | fail→fail | — | — | — | — | — | — | — | — | — | — | — | — |
DecimalAI ran this skill against gemini-3.6-flash twice over the same eval suite — once with the skill loaded and once without — and compared the two runs case by case. 22 cases were attempted. The headline lift of +18 percentage points is the difference between those two pass rates over the 22 comparable cases.
The per-case answers from this run were removed by the retention sweep, so the case table below shows the verdicts without the text either arm produced. The counts above were recorded at the time and are unaffected. Answers are now kept for 180 days.
Other measured skills in the registry, with their headline benchmark lift.